The DTC status byte
Every DTC the ECU reports through ReadDTCInformation (SID 0x19) is three bytes long: two bytes identify the fault and the third is an 8-bit status byte describing where that fault stands in its lifecycle. The same status byte appears in DTC responses, in freeze frames, and in the masks used to filter fault memory, so reading it is the foundation of DTC work.
The 8 status bits
| Bit | Name | Meaning |
|---|---|---|
| 0 | testFailed | The most recent run of the diagnostic monitor failed |
| 1 | testFailedThisOperationCycle | The test failed at least once during this operation cycle |
| 2 | pendingDTC | The fault was seen once and is waiting for confirmation |
| 3 | confirmedDTC | The DTC is confirmed and mature |
| 4 | testNotCompletedSinceLastClear | The monitor has not run since the fault memory was last cleared |
| 5 | testFailedSinceLastClear | The test failed at least once since the last clear |
| 6 | testNotCompletedThisOperationCycle | The monitor has not run during this operation cycle |
| 7 | warningIndicatorRequested | The ECU requests the warning lamp (MIL) to be on |
The most checked bits in practice are bit 3 (confirmedDTC) and bit 0 (testFailed): together they tell you whether a fault is mature and whether it is still present.
A worked example: status 0x09
in binary is 0000 1001, so bit 3 and bit 0 are set:
- Bit 3, confirmedDTC: the fault is confirmed and mature.
- Bit 0, testFailed: the most recent monitor run failed.
A DTC reported with status is confirmed and failing right now. Change the second set bit and the story changes: alone (confirmedDTC without testFailed) is a matured fault whose monitor currently passes, and alone (pendingDTC) is a fault seen once that has not matured yet.
Reading statuses with masks
Sub-function (reportDTCByStatusMask) takes a status mask and returns every DTC whose status shares at least one set bit with the mask.
Read the whole DTC memory
The mask FF matches every status bit, so the ECU returns all stored DTCs with their 3-byte records.
The response to a request begins with the status availability mask, which tells you which of the 8 status bits this ECU actually supports before you interpret the rest of the record.
A mask of (confirmedDTC only) is the usual way to ask for the faults that matter, and adds whatever is failing right now. The simulator lets you toggle each bit and see the interpretation change live.
Try it on a live ECU
The 0x19 service reference covers every sub-function, freeze frames, and extended data records, and the simulator’s DTC tools let you inject faults and read the resulting status bytes back.