SID 10 Diagnostic Session State Machine

SID 10 Diagnostic Session State Machine A lifecycle diagram generated by Archify. Power-On · or 0x11 ECU reset · Lifecycle state · initial 00 Power-On or 0x11 ECU reset initial Default Session · read-only, always available · Lifecycle state · 0x01 01 Default Session read-only, always available 0x01 Extended Session · security access, writes · Lifecycle state · 0x03 02 Extended Session security access, writes 0x03 Extended, Unlocked · seed and key accepted · Lifecycle state · unlocked 03 Extended, Unlocked seed and key accepted unlocked Programming Session · flash and reflash · Lifecycle state · 0x02 04 Programming Session flash and reflash 0x02 boot 10 03 0x27 10 02 10 02 works from any session 10 01 10 01 10 01 Legend initial state active success neutral