SID 0x3E Tester Present: Service Interaction Sequence

SID 0x3E Tester Present: Service Interaction Sequence A sequence diagram generated by Archify. 10 03: enter Extended Session 50 03 00 32 01 F4: P2* = 5000 ms 3E 00 Sent every 2500 ms (P2* / 2). Resets the P2* timeoutcounter; session type stays Extended. 7E 00 27 01 seed, 27 02 [key] 67 02: level 1 granted 3E 00 Keep-alive does not reset the security level from 0x27:level 1 stays active while the timer resets. 7E 00 10 10, 27 auth, then 34 40 01 50 10 ... (P2* = 30000 ms), 74 ... 36 01 ... 36 32 [1024 bytes each] 3E 00 Keep-alive at the 3.5 s and 15 s marks. Without it, oneblock taking over 30 s ends the session and the updatefails. 7E 00 37: RequestTransferExit 77: download complete 3E 00 (after P2* expiry) 7F 3E 22 conditionsNotCorrect 10 03: re-enter Extended Session 50 03 ... new P2* value Session entry Keep-alive cycle Security access preserved Firmware download, P2* = 30000 ms Timeout recovery Diagnostic Tester · keep-alive client · Sequence participant Diagnostic Tester keep-alive client ECU · UDS server (ISO 14229) · Sequence participant ECU UDS server (ISO 14229) Legend main request return security message