SID 0x37 ECU Processing: Practical Implementation

SID 0x37 ECU Processing: Practical Implementation A workflow diagram generated by Archify. 01 / Request Intake 02 / Transfer State 03 / Session + Security 04 / Vehicle Conditions 05 / Data + Blocks 06 / Verification + Post-Processing 07 / Response EX / Negative Responses 7F 37 XX Receive + state Access + conditions Data + verification Receive + Validate Length · SID 0x37 request · Request Intake › Receive + state Receive + Validate Length SID 0x37 request Check Transfer State · active transfer expected · Transfer State › Receive + state Check Transfer State active transfer expected Check Session + Security · Programming 0x02, SID 0x27 unlock · Session + Security › Access + conditions Check Session + Security Programming 0x02, SID 0x27 unlock Check Vehicle Conditions · voltage, temperature, vehicle state · Vehicle Conditions › Access + conditions Check Vehicle Conditions voltage, temperature, vehicle state Validate Params + Blocks · block count and transfer size · Data + Blocks › Data + verification Validate Params + Blocks block count and transfer size Verify Data + Post-Process · CRC check, flash write · Verification + Post-Processing › Data + verification Verify Data + Post-Process CRC check, flash write Return Positive 0x77 · state to IDLE, buffer cleared · Response › Data + verification Return Positive 0x77 state to IDLE, buffer cleared NRC 0x13 · incorrect message length · Negative Responses 7F 37 XX › Receive + state NRC 0x13 incorrect message length NRC 0x24 · request sequence error, most common · Negative Responses 7F 37 XX › Receive + state NRC 0x24 request sequence error, most common NRC 0x7F / 0x33 · wrong session or locked · Negative Responses 7F 37 XX › Access + conditions NRC 0x7F / 0x33 wrong session or locked NRC 0x22 / 0x92 / 0x93 · unsafe conditions or voltage · Negative Responses 7F 37 XX › Access + conditions NRC 0x22 / 0x92 / 0x93 unsafe conditions or voltage NRC 0x31 / 0x70 · count mismatch or missing blocks · Negative Responses 7F 37 XX › Data + verification NRC 0x31 / 0x70 count mismatch or missing blocks NRC 0x72 · programming failure, data discarded · Negative Responses 7F 37 XX › Data + verification NRC 0x72 programming failure, data discarded transfer active params + blocks OK length OK conditions OK session + security OK verification passed too short / too long no active transfer / already exited checksum mismatch / flash failure unsafe conditions / voltage wrong session or locked count mismatch / missing blocks Legend Agent logic Policy