SID 0x2A Service Interactions: Monitoring Workflow

SID 0x2A Service Interactions: Monitoring Workflow A sequence diagram generated by Archify. 10 03 50 03 00 32 01 F4 Session = EXTENDED (0x03), P2 =50ms, P2* = 5000ms 2A 02 01 (medium rate, PDID 0x01) 6A Acknowledgment: PDID 0x01scheduled at 100ms medium rate 27 01 (request seed) 67 01 A5 3F 7B 91 Seed A5 3F 7B 91, tester computeskey 5A C0 84 6E 27 02 5A C0 84 6E (send key) 67 02 (unlocked) 2A 01 0A (slow rate, PDID 0x0A) 6A 6A 0A 12 34 every 500ms Calibration = 0x1234 6A 01 0C 80 (RPM = 3200) 6A 02 00 3C (Speed = 60 km/h) 3E 80 (TesterPresent, suppress response) Resets the 5000ms session timer,send every ~4 seconds 2A 04 (stop sending) 6A (all periodic transmissions stopped) 10 01 (return to DEFAULT) 50 01 00 32 01 F4 Session setup Periodic request Security unlock (protected PDID) Periodic transmission Keepalive + stop Tester · diagnostic client · Sequence participant Tester diagnostic client Session Control · SID 0x10 · Sequence participant Session Control SID 0x10 SecurityAccess · SID 0x27 · Sequence participant SecurityAccess SID 0x27 0x2A Handler · request validation · Sequence participant 0x2A Handler request validation Scheduler · periodic timers · Sequence participant Scheduler periodic timers Legend main request return security async trace message